Chapter 9 Operating Instructions
DME4000
122 © SICK AG • Germany • Subject to change without notice 8014584/ZN33/2017-07
Appendix
9.6.9 Additional diagnostic data
The following parameters can be read out as additional diagnostic data:
Reception level
Description Get single Attribute
Class 64
Instance 1
Attribute: 11
Received Information Example: B0 0 x 100 0 x B0 = 0 x 47 -71dB
Error status
Description Get single Attribute
Class 64
Instance 1
Attribute: 12
Received Information Example: 0 x 09 0000 1001
MF2
MF1
TMP
LSR
BUS
ATT
PLB
RDY
0
0
0
0
1
0
0
1
Icon BUS und RDY can be seen in the display.