Technical specifications
8.10 SFP technical specifications
SCALANCE X-300
Operating Instructions, 02/2012, A5E01113043-12
221
8.10.4 Other properties of SFP
Table 8- 136 MTBF
Device:
transceiver
(Variant) MTBF
SFP991-1 (1 x 100 Mbps, LC port
optical, multimode glass, up
to max. 3 km)
> 120 years
SFP991-1LD (1 x 100 Mbps, LC port
optical, single mode glass,
up to max. 26 km)
> 120 years
SFP991-1LH+ (1 x 100 Mbps, LC port
optical, single mode glass,
up to max. 70km)
> 120 years
SFP992-1 (1 x 1000 Mbps, LC port
optical, multimode glass, up
to max. 750m)
> 120 years
SFP992-1LD (1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 10km)
> 120 years
SFP992-1LH (1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 40km)
> 120 years
SFP992-LH+ (1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 70km)
> 120 years
SFP992-1ELH (1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 120km)
> 120 years
Note
The IE Switches X-300 support full wire speed switching complying with IEEE 802.3 on all
ports.
The number of packets depends on the packet length according to the IEEE802.3 standard:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X308-2M and is the answer not in the manual?

Siemens SCALANCE X308-2M Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X308-2M
CategoryNetwork Router
LanguageEnglish

Related product manuals