Description of the device
4.3 Interfaces and signaling contact of the switches
SCALANCE X-300
92 Operating Instructions, 02/2012, A5E01113043-12
Transmission medium
Data is transmitted over single mode FOC. The wavelength is 1310 nm or 1550 nm.
The core diameter of the single mode FO cable is 9 or 10 µm; the light source is a laser
diode. To transmit a signal, only one mode (light beam) is used greatly reducing dispersion.
As a result, the maximum range of single mode FOC is greater than that of multimode FOC.
Transmission range
The maximum transmission distance (segment length) is 120 km for 1000Base-LX
transmission.
IE Switches X-300 connector technology
SC duplex female connectors are used.
Connector technology of the IE Switch X-300EEC
FC duplex female connectors with the following characteristics are used:
Maximum range: up to 3 km
Wavelength: 1310 nm
Transmission mode: Multimode
Standard: 100Base-FX
4.3.3 Signaling contact
The signaling contact (relay contact) is a floating switch with which error/fault states can be
signaled by breaking the contact.
Error indication
The signaling by the signaling contact is synchronized with the fault LED, in other words,
all errors displayed by this LED (freely configurable) are also signaled on the signaling
contact.
If an internal fault occurs, the fault LED lights up and the signaling contact opens.
The connection or disconnection of a communication node on an unmonitored port does
not lead to an error message.
The signaling contact remains activated until the error/fault is eliminated or until the
current status is entered in the fault mask as the new desired status.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X308-2M and is the answer not in the manual?

Siemens SCALANCE X308-2M Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X308-2M
CategoryNetwork Router
LanguageEnglish

Related product manuals