Approvals, certificates, standards
9.8 MM900 product group
SCALANCE X-300
Operating Instructions, 02/2012, A5E01113043-12
263
9.7.3 XR-300M PoE mechanical stability in operation
The switch meets the following requirements for mechanical stability:
IEC 60068-2-6 (vibration)
Mounting in the rack: (2-point mounting:)
10 to 58 Hz: 0.075 mm
85 – 150 Hz: 1 g
1 octave/min, 20 sweeps
Individual mounting: (4-point mounting):
5 to 8.51 Hz: 3.5 mm
8.51 – 500 Hz: 1 g
1 octave/min, 20 sweeps
IEC 60068-2-27 (shock)
Mounting in the rack (2-point mounting):
15 g, 11 ms duration, 6 shocks per axis
9.8 MM900 product group
9.8.1 MM900 approvals, certificates
NOTICE
Issued approvals on the type plate of the device
The specified approvals apply only when the corresponding mark is printed on the product.
You can check which of the following approvals have been granted for your product by the
markings on the type plate.
EC directives
SIMATIC NET products meet the requirements and aims of the following EC directives.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X308-2M and is the answer not in the manual?

Siemens SCALANCE X308-2M Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X308-2M
CategoryNetwork Router
LanguageEnglish

Related product manuals