9.6.4 X-300M PoE mechanical stability in operation
The switch meets the following requirements for mechanical stability:
IEC 60068-2-6 (vibration)
Securing on a DIN rail
5 – 9 Hz: 3.5 mm
9 – 150 Hz: 1 g
1 octave/min, 20 sweeps
IEC 60068-2-27 (shock)
Securing on a DIN rail
15 g, 11 ms duration, 6 shocks per axis
9.7 Product group XR-300M PoE
9.7.1 XR-300M PoE approvals, certificates
Note
The specified approvals apply only when the corresponding mark is printed on the product.
You can check which of the following approvals have been granted for your product by the
markings on the type plate.
EC directives
SIMATIC NET products meet the requirements and aims of the following EC directives.