Technical data
16.2 Technical specifications of CPU 410E (6ES7410-5HM08-0AB0)
CPU 410 Process Automation/CPU 410 SMART
272 System Manual, 05/2017, A5E31622160-AC
• Number of instances for alarm 8 and S7
communication blocks, max.
10 000
• preset, max.
10 000
Test commissioning functions
Status block Yes
• Status/control variable
Yes
• Variables
Inputs/outputs, memory bits, DBs, distributed
• Number of variables, max.
70
• present
Yes
• Number of entries, max.
3 200
• can be read out
Yes
Standards, approvals, certificates
• ATEX
ATEX II 3G Ex nA IIC T4 Gc
Ambient temperature during operation
• min.
0 °C
• max.
70 °C
• User program protection/password protec-
tion
Yes
• Block encryption
Yes; With S7 block Privacy