Commissioning (software)
6.9 Setting up addresses and message frames
SIMOTION D4x5-2
244 Commissioning and Hardware Installation Manual, 02/2012
6.9.2 Message frame configuration
Requirement
You have configured the drive unit.
On the basis of this configuration, one or more of the following actions should be performed:
The automatic PROFIdrive message frame setting for a drive object should be
activated/deactivated
The automatic message frame extension for a drive object should be
activated/deactivated
The automatic address adaptation for a drive object should be activated/deactivated
PROFIdrive message frames should be configured for drive objects
The addresses should be set up
Message frames should be extended manually
Procedure
Proceed as follows:
In the project navigator, open the "Communication" > "Message frame configuration" entry
under "SINAMICS_Integrated".
The "SINAMICS Integrated - Message Frame Configuration" dialog box is displayed with the
PROFIdrive PZD message frames tab.
The dialog box lists all the available drive objects. The possible setting options are described
in the following.
When using the symbolic assignment, the default setting does not have to be changed and
no configuration performed.

Table of Contents

Other manuals for Siemens SIMOTION D455-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D455-2 and is the answer not in the manual?

Siemens SIMOTION D455-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D455-2
CategoryControl Unit
LanguageEnglish

Related product manuals