Description
1.5 Safety information
SIMOTION D4x5-2
26 Commissioning and Hardware Installation Manual, 02/2012
1.5 Safety information
Note the following safety information when working with the Control Unit and its components.
NOTICE
The 80 mm clearances above and below the components must be observed. The unit
protects itself from overheating by shutting down.
CAUTION
An option board may only be inserted and removed when the Control Unit and option board
are disconnected from the power supply.
The CompactFlash card may only be inserted or removed when the Control Unit is
disconnected from the power supply.
The SIMOTION D4x5-2 is in a de-energized state when all the LEDs are off.
WARNING
Safe, problem-free operation of SIMOTION D Control Units assumes proper transportation,
storage, setup, and installation, as well as careful operation and maintenance.
In addition to the danger and warning information provided in the technical customer
documentation, the applicable national, local, and plant-specific regulations and
requirements must be taken into account.
Only safety extra-low voltage in accordance with EN/IEC 60950-1 may be connected to all
connections and terminals.

Table of Contents

Other manuals for Siemens SIMOTION D455-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D455-2 and is the answer not in the manual?

Siemens SIMOTION D455-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D455-2
CategoryControl Unit
LanguageEnglish

Related product manuals