Operation
9.1 Basic information
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
365
9.1.5.1
Binectors, connectors
Binectors, BI: Binector input, BO: Binector output
A binector is a digital (binary) signal without a unit which can assume the value 0 or 1.
Binectors are subdivided into binector inputs (signal sink) and binector outputs (signal
source).
Table 9- 3 Binectors
Abbreviation
Symbol
Name
Description
BI
Binector input
(signal sink)
Can be interconnected to a binector output as
source.
The number of the binector output must be
entered as a parameter value.
BO
Binector output
(signal source)
Can be used as a source for a binector input.
Connectors, CI: Connector input, CO: Connector output
A connector is a digital signal, e.g. in 32-bit format. It can be used to emulate words (16 bits),
double words (32 bits) or analog signals. Connectors are subdivided into connector inputs
(signal sink) and connector outputs (signal source).
Table 9- 4 Connectors
Abbreviation
Symbol
Name
Description
CI
Connector input
(signal sink)
Can be interconnected to a connector output as
source.
The number of the connector output must be
entered as a parameter value.
CO
Connector output
(signal source)
Can be used as a source for a connector input.

Table of Contents

Other manuals for Siemens SINAMICS DCM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS DCM and is the answer not in the manual?

Siemens SINAMICS DCM Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS DCM
CategoryMedia Converter
LanguageEnglish

Related product manuals