Description
SINAMICS DCM DC Converter
36 Operating Instructions, 12/2018, A5E34763375A
Versions
The armature supply is available in the following versions:
2-quadrant units:
The armature is supplied via a fully-controlled three-phase bridge (B6C).
4-quadrant units:
The armature is supplied via two fully-controlled three-phase bridges connected in a
circulating-current-free inverse-parallel configuration ((B6)A(B6)C).
The field supply is available in the following versions:
1-phase, single-pair controllable two-pulse bridge circuit (B2HZ)
1-phase, fully-controlled two-pulse bridge circuit (B2C) (option)
The electronics (CUD) are available in the following versions:
Standard CUD
Advanced CUD (option)
This CUD can be expanded to include a PROFINET module (CBE20) and features
2 DRIVE-CLiQ connections for connecting additional components from the SINAMICS
drive system, as well as a connector for expansion purposes (to include a second CUD).
Additional (second) CUD (Standard CUD or Advanced CUD) (option)
This additional CUD can be fitted to the right of the first CUD and is used for system-
specific extension of the SINAMICS DC MASTER functions.
Additional components
Advanced Operator Panel AOP30
The optional Advanced Operator Panel AOP30 is installed outside of the unit in the
control cabinet door, for example rather than inside it.
The AOP30 ensures the following additional comfort:
Commissioning is supported by a wizard.
Measured values are represented by a graphical operation screen.
Displays a user-friendly parameter list, including text.
There are several editors for user-friendly setting and changing of parameters.
As well as help texts on individual faults and alarms, the fault and alarm messages
which occur are listed.
Control of the drive (ON/OFF, setpoint specification, jog, direction of rotation reversal)
is enabled "on-site".
Three LEDs display the drive status.
Additional module CBE20
The additional module CBE20 is inserted in the optional module slot of an Advanced
CUD. It enables the SINAMICS DC MASTER to access the
PROFINET
network as a
slave as well as to establish
SINAMICS Link
connections.

Table of Contents

Other manuals for Siemens SINAMICS DCM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS DCM and is the answer not in the manual?

Siemens SINAMICS DCM Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS DCM
CategoryMedia Converter
LanguageEnglish

Related product manuals