Descriptions of functions
10.30 Serial interface with peer-to-peer protocol
SINAMICS DCM DC Converter
624 Operating Instructions, 12/2018, A5E34763375A
10.30
Serial interface with peer-to-peer protocol
General information
The peer-to-peer interface enables BICO interconnections across several SINAMICS DCMs,
As well as allowing the peer-to-peer interface to establish signal connections between
converters in the SINAMICS DC MASTER range (order number = 6RA80...) and converters
in other ranges, such as SIMOREG DC-MASTER (order number = 6RA70...) and
SIMOREG K (order number = 6RA24...).
Properties
A "peer-to-peer connection" refers to "a connection between partners with equal status".
Unlike the classic master-slave bus systems (such as PROFIBUS or USS), peer-to-peer
connections enable the same converter to act as both a master (setpoint source) and a slave
(setpoint recipient).
Signals can be transferred via the peer-to-peer connection from one converter to another in
fully digital format.
Velocity setpoints
for creating a setpoint cascade, e.g. in paper making machines, film
manufacturing machines, and wire drawing machines, as well as fiber stretching plants
Torque setpoints
for load distribution control systems on drives that are coupled either
mechanically or by means of the material, e.g. horizontal-shaft drives on a printing
machine or S-roll drives
Acceleration setpoints (dv/dt)
for acceleration precontrol in multi-motor drives
Control commands
The peer-to-peer interface uses the RS485 interface at connector X177 (terminals 37, 38,
39, and 40).
Function diagrams
Function diagram FP9300 shows the settings and BICO interconnection options for the
"peer-to-peer connection".
Diagnostics
Parameter r50799 contains information about the distribution of error-free telegrams and
telegrams with errors over time, as well as the type of any communications errors that occur.

Table of Contents

Other manuals for Siemens SINAMICS DCM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS DCM and is the answer not in the manual?

Siemens SINAMICS DCM Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS DCM
CategoryMedia Converter
LanguageEnglish

Related product manuals