EasyManuals Logo

Siemens SINAMICS DCM User Manual

Siemens SINAMICS DCM
758 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
Technical data
4.2 Duty cycles for 2Q applications
SINAMICS DCM DC Converter
40 Operating Instructions, 12/2018, A5E34763375A
Note
•
If a value > 1 is set at p50067, you need to make sure that the "Dynamic overload
capability of the power unit" is enabled. This requires a value > 0 to be set at p50075.
•
The SINAMICS DC MASTER does not monitor whether the load class set using p50067
is being adhered to. If the power unit permits it, longer overload periods can be used than
those that correspond to the load class.
The actual permissible overload duration for the particular power unit is always greater
than the overload duration corresponding to the particular load class. SINAMICS DC
MASTER monitors whether the overload duration that is actually permitted for the power
unit is being maintained. For details on the power unit'
s dynamic overload capability, refer
to Chapter "Dynamic overload capability of the power unit (Page 591)".
•
The 100% I
DCx
shown previously DO NOT generally correspond to the rated unit current,
but are reduced according to the subsequent table.
4.2
Duty cycles for 2Q applications
Table 4- 2 Duty cycles for 2Q applications
SINAMICS
DCM
6RA80..
Duty cycles
Tu DC I
continuous
DC II DC III DC IV US rating
Tu = 45 °C
15 min
100%
60 s
150%
15 min
100%
120 s
150%
15 min
100%
10 s
200%
15 min
100%
60 s
150%
°C A A A A A A A A A
400 V, 2Q
.25-6DS22
45
60
51.4
77.1
50.2
75.3
46.4
92.8
51.4
77.1
.28-6DS22
45
90
74.4
111
72.8
109
65.4
130
74.4
111
.31-6DS22
45
125
106
159
103
155
96.3
192
106
159
.75-6DS22
40
210
164
247
161
242
136
273
157
236
.78-6DS22
40
280
226
340
219
328
201
402
215
323
.81-6DS22
40
400
290
435
282
423
244
488
278
417
.85-6DS22
40
600
462
693
446
669
413
826
443
665
.87-6DS22
40
850
652
978
622
933
609
1219
619
929
.91-6DS22 40 1200 884 1326 857 1286 768 1537 842 1263
.93-4DS22
40
1600
1255
1883
1213
1819
1139
2279
1190
1785
.95-4DS22
40
2000
1477
2216
1435
2152
1326
2653
1404
2106
.98-4DS22
40
3000
2288
3432
2189
3283
2164
4328
2178
3267

Table of Contents

Other manuals for Siemens SINAMICS DCM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS DCM and is the answer not in the manual?

Siemens SINAMICS DCM Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS DCM
CategoryMedia Converter
LanguageEnglish

Related product manuals