5-16
11. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject Clear chart
(Color bar standard picture frame)
Filter Filter C14 for color temperature
correction
Measurement Point DDS display of LCD or TV monitor
Measuring Instrument (Note 1)
Adjustment Page F
Adjustment Address 34, 35
Specified Value R ratio: 2B40 to 2BC0
B ratio: 5E40 to 5EC0
Note 1: Perform “Auto White Balance Standard Data Input” before this
adjustment.
Note 2: The right four digits of the display data at the right bottom side of
the LCD and TV monitor is the object data.
CA 00 XXXX
Object data
Switch setting:
1) NIGHT SHOT switch ......................................................OFF
Adjusting method:
1) Place the C14 filter for color temperature correction on the
lens.
2) Select page: 0, address: 01, and set data: 01.
3) Select page: D, address: 11, and set data: 02, and press the
PAUSE button of the adjustment remote commander.
4) Select page: 6, address: 00, and set data: 01.
5) Select page: 6, address: 01, and set data: 3F, and press the
PAUSE button of the adjustment remote commander.
6) Select page: 6, address: 04, and set data: 04.
7) Select page: F, address: 34, change the data and adjust the
average value of the DDS display data (Note 2) to the R ratio
specified value.
8) Press the PAUSE button of the adjustment remote commander.
9) Select page: 6, address: 04, and set data: 05.
10) Select page: F, address: 35, change the data and adjust the
average value of the DDS display data (Note 2) to the B ratio
specified value.
11) Press the PAUSE button of the adjustment remote commander.
Processing after Completing Adjustments:
1) Select page: D, address: 11, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 6, address: 00, and set data: 00.
4) Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
5) Select page: 6, address: 04, and set data: 00.
12. White Balance Check
Subject Clear chart
(Color bar standard picture frame)
Filter Filter C14 for color temperature
correction
ND filter 1.0 and 0.3
Measurement Point Video output terminal
Measuring Instrument Vectorscope
Specified Value Fig. 5-1-10. (A) to (C)
Switch setting:
1) NIGHT SHOT switch ......................................................OFF
Checking method:
1) Check that the lens is not covered with either filter.
2) Select page: 6, address: 01, set data: 0F, and press the PAUSE
button of the adjustment remote commander.
3) Check that the center of the white luminance point is within
the circle shown Fig. 5-1-10 (A).
4) Select page: 6, address: 01, set data: 23, and press the PAUSE
button of the adjustment remote commander.
5) Place the C14 filter on the lens.
6) Check that the center of the white luminance point settles in
the circle shown Fig. 5-1-10 (B).
7) Remove the C14 filter, and place the ND filter 1.3 (1.0 + 0.3)
on the lens.
8) Check that the white luminance point stopped moving, and then
remove the ND filter 1.3.
9) Check that the center of the white luminance point settles within
the circle shown Fig. 5-1-10 (C).
Processing after Completing Adjustments:
1) Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.