14
SAFETY NOTES SELF DIAGNOSIS FUNCTION TROUBLESHOOTING SERVICE ADJUSTMENT DIAGRAM HANDLING GUIDE
Self Diagnosis Service Menu
Entry (Self Diagnosis Display)
- Go to the standby by a remote.
- Push the buttons sequentially:
<Display> or <i+(info)>
<5> <Vol-> <Power> OR
<Home> <DpadCenter> <Vol-> <Power>.
Exit
- If you want to finish service mode app, do AC OFF/ON.
→*Service mode app is disable perfectly.
- If you want to move home menu, push <HOME> button.
→*Service mode app do background (not disable perfectly).
002 MAIN POWER 050121081135 041231123456 031111182547 003
003 DC ALERT 000000000000 000000000000 000000000000 000
003 AUD ERR 000000000000 000000000000 000000000000 000
003 AUD ERR I2C 000000000000 000000000000 000000000000 000
003 TU DEMOD I2C 000000000000 000000000000 000000000000 000
005 TCON ERR 000000000000 000000000000 000000000000 000
005 P ID ERR 000000000000 000000000000 000000000000 000
006 BACKLIGHT ERR 000000000000 000000000000 000000000000 000
007 TEMP ERR 000000000000 000000000000 000000000000 000
007 TEMP ERR I2C 000000000000 000000000000 000000000000 000
SELF CHECK
00034 00231 00034
Back
[Home]Exit [Up/Down]Scroll
SELF DIAGNOSIS FUNCTION
Self Diagnosis Display [Example]
SYSSET