EasyManuals Logo
Home>Sony>Switch>MVS-6520

Sony MVS-6520 User Manual

Sony MVS-6520
454 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #368 background imageLoading...
Page #368 background image
USO RESTRITO
368
GPI Output Settings
No.
Parameter
Adjustment
1
From Slot
First port slot
2
From Port
First port number
3
To Slot
Last port slot
4
To Port
Last port number
Chapter
21
DCU
Setup
Parallel Output Port: 1 to 36
4
Press [GPI Output Set].
Releasing the Assignment of a GPI
Output Port
1
In the Engineering Setup >DCU >Output Config menu
(7353), select what the setting applies to (DCU1 or
DCU2) from the <DCU Select> group.
2
In the <Parallel Output Assign> group, if [GPI Output]
is on, press it to turn it off.
3
Select the slot and port to which the setting applies.
4
In the <Parallel Output Assign> group, press [No
Assign].
GPI Output Settings
This sets the trigger type and so on for each GPI output.
Making DCU GPI Output Settings
1
In the Engineering Setup >DCU >GPI Output Assign
menu (7354), select what the setting applies to.
2
In the <Trigger Type> group, select the trigger type.
(Rising Edge): The trigger causes the relay
contacts to be open-circuit or drives the output
high, and holds this state for the specified pulse
width.
(Falling Edge): The trigger causes the relay
contacts to be shorted or drives the output low, and
holds this state for the specified pulse width.
(Any Edge): Each time the trigger occurs, the
relay contacts are alternately closed or opened, or
the output is switched between high and low.
Status: Depending on the status, the relay contacts are
closed or opened, or the output is switched
between high and low.
No Operation: The trigger has no effect on the relay
state or output level.
3
Select the pulse width and timing to be set.
No.
Parameter
Adjustment
3
Pulse Width
Pulse width
4
Timing
Output timing
a)
a)
1: Field 1, 2: Field 2, 3: Any
When is selected as the trigger polarity, there is
no Pulse Width setting. When “Status” is selected,
there is no Pulse Width or Timing setting.
4
In the <Source Device> group, select the control panel
or DCU to handle the GPI output.
Notes
The SCU2 setting is disabled.
When the action set in the following step 5 is carried
out on the control panel selected here, this causes a
GPI output. It is also possible to output error
information.
When the DCU is selected, you can output error
information by means of the action set in step 5.
5
In the list on the right, select the action.
6
Press [Action Set] to confirm the action selection.
Selectable actions for various trigger types
When the trigger type is other than “Status”
(The x in M/E-x is the M/E bank number, the x in DSKx
is the DSK number, and the x in Keyx is the key
number.)
When Source Device is SCU: M/E-x Keyx SS ? Recall,
P/P DSKx SS ? Recall, No Action
When Source Device is DCU: No Action
When the trigger type is “Status”
(The x in M/E-x is the M/E bank number, the x in DSKx
is the DSK number, and the x in Keyx is the key
number.)
When Source Device is SCU: M/E-x Keyx SS ? Recall,
P/P DSKx SS ? Recall, M/E-x Keyx On, P/P DSKx
On, Error Make, Error Break, Keep Make, Keep
Break, Device Recording, No Action
When Source Device is DCU: Error Make, Error Break,
No Action
Test firing the trigger
Press [Test Fire].
This outputs a trigger from the selected output port. This is
no output when the trigger type is “Status.”

Table of Contents

Other manuals for Sony MVS-6520

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sony MVS-6520 and is the answer not in the manual?

Sony MVS-6520 Specifications

General IconGeneral
BrandSony
ModelMVS-6520
CategorySwitch
LanguageEnglish

Related product manuals