98
figure 8-19 Reactive Power Regulation
table 8-9 Description of reactive power regulation
Parameter
Description
Default
Range
Reactive Power
Setting
Persistence
Switch for activating/deactivating the
function of reactive power setting
persistence
On On / Off
Reactive Power
Regulation Mode
See "8.5.3 Reactive Power Regulation
Mode"
Off
Off / PF /
Qt / Q(P) /
Q(U)
Reactive
Response
Reactive response function on and off
On On / Off
Reactive Re-
sponse Time
Reactive power response time
30.0s
0.1s
600s
Reactive Power
Ratio
Ratio of reactive power
0.0%
0.0%
100%
8.10.8 Battery Discharge Time
Tap Settings→Energy Management Parameter→Battery Discharge Time to enter the
corresponding screen, as shown in the following figure.
These are the times of day at which the battery is allowed to discharge to the house loads.