figure 8-27 Energy Management Mode
Parameter
Description
Self-Consumption Mode
The normal operation mode of the inverter, where the inver-
ter will cover the house load with PV and battery power. if
the PV is higher than the load and the battery is full, the
power will be injected in the grid according to the Feed-in
Limitation settings.
Compulsory Mode
The Force Charge or Force Discharge of the battery. Set
the Force Charge or Discharge power and the battery will
charge/discharge to the house load or the grid.
External Energy
Dispatch
The inverter is controlled by an external energy manage-
ment system through Modbus RTU or TCP.
8.10.18 DO Configuration
Tap Settings→Operation Parameters→Regular Parameters→DO Configuration to en-
ter the screen, as shown in the following figure.
8 iSolarCloud App User Manual