COOLING
AND
LUBRICATION
SYSTEM
6-7
RADIATOR CAP
INSPECTION
Remove the radiator cap.
(-6-3)
Fit the cap
@
to the radiator cap tester
@.
Build up pressure slowly by operating the tester. Make sure
that the pressure build-up stops at 95
-
125 kPa (0.95
-
1.25
kgflcmz, 13.5
-
17.8
psi) and that, with the tester held stand-
still, the cap
is
capable of holding that pressure for at least
10
seconds.
Replace the cap
if
it is found not to satisfy above require-
ments.
Radiator cap valve opening pressure
Standard: 95
-
125 kPa
(0.95
-
1.25 kgf/cm2, 13.5
-
17.8 psi)
WATER HOSE
INSPECTION
Remove the cowling.
(-7-5)
Any water hose found in a cracked condition or flattened or
water leaked must be replaced.
Any leakage from the connecting section should be corrected by
proper tightening.