2. Maintenance Information
2-20
Battery
Battery removal
Remove the left side cover.
Remove the〝─〞negative pole first, then
remove the〝+〞positive pole.
Unplug the ventilation tube
Remove the battery holder and take out the
battery.
If the battery liquid level is too low, please
remove the top plug, and fill in distilled water
to the upper limit.
Caution:
z Don’t fill in too much distilled water, or the
electrolyte may overflow and corrode the
frame.
z Only distilled water is allowed. If any
impure water is filled in, it will shorten the
battery life.
Warning:
z The electrolyte contained sulfuric acid.
Please avoid touching the eyes, skin, or
clothes. If any contact by accident, please
flush with plenty of water.
If there is some rust on battery posts, clean
it with steel brush
Install the battery in the reverse procedures
of removal
Caution:
z If the rust on the posts is very serious,
spray some hot water on them. Then,
more easily you can remove the rust by
steel brush.
z Apply some grease on the posts after
cleaning rust to prevent from
happening again.
Negative pole