5-42
MAINTENANCE
INSPECTING THE REFRIGERANT (GAS)
LEVEL (AC)
• Exposure of the eyes or hands to the
cooler’s refrigerant could result in
blindness or frostbite.
Never touch the refrigerant or loosen
the parts of the cooling circuit.
• Keep flames away if the refrigerant gas
is leaking.
• The high-pressure pipes of the air
conditioner can be very hot (80 to 120°C
or 176 to 248°F). Be careful not to burn
yourself.
The cooling capacity decreases if the
amount of refrigerant is insufficient.
Inspect the refrigerant level using the sight
glass (2) on the top of the receiver dryer (1).
EVERY 250 HOURS
1. Open the engine hood.
2. Inspect the places for the conditions
below.
Places for inspection
Conditions
Cab door Fully open
Temperature control
dial
Set fully to the COOL
side
Fan speed High
Ventilation/
Circulation select
lever
Circulation
Engine speed Maximum speed
Air conditioner
switch
ON
3. Inspect the refrigerant by watching the
flow of air bubbles through the sight glass
(2).
Refer to “Check list for refrigerant volume”
on page 5-43.
4. Check the temperature of the
compressor’s high pressure pipe (3) and
low pressure pipe (4).
Refer to “Check list for refrigerant volume”
on page 5-43.