Using the ARIB Di
splays
Using the ARIB Displays
Your instrument supports conformance to ARIB data standards contained in the signal source. This information is contained
in the following screen displays:
ARIB Status
ARIB STD-B.39 Display
ARIB STD-B.37 Display
ARIB STD-B.35 Display
ARIB TR-B.23 (1) D isplay
ARIB TR-B.23 (2) D isplay
ARIB TR-B.22 Display
The following DID and SDID values are dened for common types of ARIB-compliant data.
DID and SDID values for common ARIB data types
Ancillary data type DID value SDID value
ARIB TR-B.22, Sub Information of transmitting materials
0x5F 0xE0
ARIB TR-B.23, Line 20 User Data - 1 0x5F
0xFC
ARIB TR-B.23, Line 20 User Data - 2 0x5F 0xFB
ARIB STD-B.35 Trigger Signal for Data Broadcasting
0x5F 0xFD
ARIB STD-B.37 Closed Captioning
Analog signal
SD signal
HD signal
0x5F
0x5F
0x5F
0xDD
0xDE
0xDF
ARIB STD-B.39 Inter Stationary Control Data
ARIB specication
ITU specication
0x5F
0x43
0xFE
0x01
To Enable the ARIB Content
Displays
1. Press the CONFIG button to display the
Conguration menu.
2. Use the Arrow keys and the SEL
button in the steps that follow to make
selections.
3. Select Aux Data Settings.
4. Select ARIB Content Display.
5. Select Enable to access the ARIB
displays and alarms; or Disable to block
access.
Waveform Monitors Quick Start User Manual 75

Table of Contents

Other manuals for Tektronix WFM6120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix WFM6120 and is the answer not in the manual?

Tektronix WFM6120 Specifications

General IconGeneral
BrandTektronix
ModelWFM6120
CategoryMonitor
LanguageEnglish

Related product manuals