OM 25-3503 us – Edition 4.1 * 2503_3503b340.fm 3-113
Operation
Automatic regeneration mode
The automatic regeneration mode is preset if the engine is stopped for at least 30 sec-
onds.
NOTICE
Fire hazard in the exhaust system
• There must be no easily flammable material in the direct vicinity of the muf-
fler, in particular near the end pipe.
• In environments with easily flammable material, disable the automatic
regeneration mode.
If the particulate matter catalyst has reached a certain contamination level, indicator light B
illuminates and an automatic regeneration is performed soon.
Indicator light C illuminates in addition during regeneration.
Information!
The machine can be operated as usual during regeneration.
Disabling/interrupting the automatic regeneration mode:
Press and hold push button A at least 3 seconds in position 1.
➥ Indicator light D illuminates.
To re-enable the automatic regeneration mode:
Press and hold push button A at least 3 seconds in position 1.
➥ Indicator light D goes out.
Information!
Disabling regeneration increases the contamination level in the particulate filter.
Fig. 258Fig. 258
1
A
Fig. 259
B C D

Table of Contents