3-114 OM 25-3503 us – Edition 4.1 * * 2503_3503b340.fm
Operation
Manual regeneration
Starting manual regeneration
Indicator light B illuminates and indicator light E flashes.
➥ Manual regeneration is possible only in this case and has to be started.
☞ Drive the machine out of the danger zone and into a safe area.
☞ Apply the parking brake.
☞ Press and hold push button A at least 10 seconds in position 3.
➥ Indicator lights B and C illuminate during regeneration.
Interrupting manual regeneration
Press and hold the Regeneration push button at least 3 seconds in position 1.
NOTICE
Possible damage to engine or particulate filter.
• Perform a complete regeneration cycle
NOTICE
Fire hazard in the exhaust system.
• There must be no easily flammable material in the direct vicinity of the
exhaust system, in particular near the end pipe.
• Do not perform manual regeneration in environments with easily flammable
material.
Regeneration not performed – stopping the machine
Engine power is reduced if indicator lights B and F illuminate and if indicator light E
flashes.
Stop the engine immediately and contact a Wacker Neuson service center.
Fig. 260Fig. 260
1
A
2
3
Fig. 261
B
C
E F