3-10 OM 803 us – Edition 3.7 * * 803b320.fm
Operation
3.5 Machine travel
Starter
Throttle
Speed is set continuously with throttle 13.
➥Position A: idling speed
➥Position B: max. engine speed
1
0
2
3
Fig. 49: Preheating start switch
4
Position Function Power consumer
0 Insert or remove the starting key None
1 ON/travel position
Feed pump switched on
➥Indicator lights illuminate
2 Preheats the engine (10 – 15 seconds) Glow plugs
3 Starts the engine
Starter
Fig. 50: Engine speed control (up to serial no. AI00814)
13
B
A
Fig. 51: Engine speed control (from serial no. AI00815)
13
B
A