Repairs
REP 10.16 Fuser Pressure Roller and Bearings
Parts List on PL 10.11 Item 3
Removal
This procedure lists steps to remove the Pressure Roller and Bearings from the Fuser. A spring
hook is recommended for this procedure.
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
WARNING
Do not touch the Fuser while it is hot.
CAUTION
Fuser plastic and metal components are easily over stressed, bent, or broken. Use care when
releasing hooks that secure Fuser covers and guides.
1. Remove the Rear Door, REP 28.6.
2. Remove the Fuser, REP 10.10.
3. Remove the Fuser Heat Roller and Bearings. REP 10.15.
4. Release the right cam follower spring.
5. Remove 2 screws with washers (1 metal, 1 plastic) that secure the cam follower to the
Fuser, Figure 1.
Figure 1 Remove the cam follower
6. Remove the Pressure Roller from the Fuser by first lifting the right end of the roller up.
Next, move the roller to the right to release the roller shaft from the left cam follower. Now
lift the left end of the roller up to remove the roller from the Fuser.
7. Remove the Pressure Roller Bearings from the cam followers, Figure 2.