EasyManuals Logo
Home>Xilinx>Computer Hardware>ChipScope Pro

Xilinx ChipScope Pro User Manual

Xilinx ChipScope Pro
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #101 background imageLoading...
Page #101 background image
ChipScope Pro Software and Cores User Guide www.xilinx.com 101
UG029 (v14.3) October 16, 2012
ChipScope Pro Analyzer Features
IBERT Spartan-6 FPGA GTP Sweep Test Panel
Sweep Test Settings Panel
The Sweep Test Settings panel is used to set up a channel test that sweeps through various
transceiver settings. The TX and RX settings are for the same GTP transceiver. Sweeping
through both TX and RX settings only works if the transceiver is set to one of the near-end
or external loopback modes. Sweeping through RX parameters only can be performed
when the corresponding TX endpoint for the link resides in a different device or a different
transceiver in the same device.
The Sweep Test Settings panel consists of four sections: the Parameter Settings section,
the Sampling Point Region section, the Test C ontr ols section, and the Test Results
section.
Parameter Settings
Setting up the sweep test first involves setting up the sweep parameters.
The GTP transceiver parameters that are available for sweep default to the following:
• TX Diff Swing
• TX Pre-Emphasis
• RX Eq
The sweep parameters can be initialized in one of two ways:
• Click the Clear All button to clear all parameters and set them to their defaults under
the Select… option.
• Click the Set Sweep Params to Current MGT Values button to set the parameters to
their current values on the MGT/BERT Settings panel.
The order of the parameters in the Sweep Parameter table dictates how the parameters are
swept. The values of the parameters near the top of the table are swept less frequently than
the parameters near the bottom of the table. In other words, the parameters near the top of
the table are in the outer loops of the sweep algorithm while the parameters near the
bottom of the table are in the inner loops of the sweep algorithm.
Each parameter must be set up with a start and end value. The order of the parameter
values cannot be changed. After you select the start value, the end values available for
selection change automatically to include only valid selections. If you do not want to
sweep through a parameter, set the start and end values for that parameter to the same
value. The # of Values column indicates how many values are swept through for a
particular parameter. After all sweep parameters have valid start and end values, the total
number of sweep iterations are shown in the Iteration field in the Test Results panel.
To add or remove items in the table, click the Add/Remove Parameters button. This opens
a dialog box with all available ports/attributes on the left, and the ones to sweep on the
right. To add new parameters to sweep, click it in the left-hand list, and click the > button.
To remove a parameter to sweep, click it in the right-hand list, and click the < button. To
specify the sweep order of the parameters, click it in the right-hand list, and then the Up or
Down buttons. To revert the sweep attributes and their order to the default setting, click
the Reset to Default button. Click OK to apply the settings, or Cancel to exit without
saving.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xilinx ChipScope Pro and is the answer not in the manual?

Xilinx ChipScope Pro Specifications

General IconGeneral
BrandXilinx
ModelChipScope Pro
CategoryComputer Hardware
LanguageEnglish

Related product manuals