8 Electrical Installation
YASKAWA TOEPC71061752B GA500 Drive Installation & Primary Operation 63
Mode Internal Power Supply (Terminal SN-SP) External 24 V power supply
Sinking
Mode (NPN)
Sourcing
Mode (PNP)
Pulse Train Output
You can use pulse train monitor output terminal MP for sourcing mode or for sinking mode.
Use for sourcing mode
The load impedance changes the voltage level of the pulse train output signal.
Load Impedance
R
L
(kΩ)
Output Voltage
V
MP
(V)
1.5 or more 5 V or more
4.0 or more 8 V or more
10 or more 10 V or more
Note:
Use the formula in Figure 8.15 to calculate the necessary load resistance (kΩ) to increase output voltage V
MP
(V).