7.4 Malfunctions when stopping
Runout noises
Possible causes Remedy
Turbochar-
ger
Turbocharger contaminated Clean (see chapter Periodic maintenance work
39)
Bearing damaged Check clearances (see chapter Axial clearance A
and radial clearance B 71). If clearances are
outside the tolerance or if in doubt, contact an
ABB Turbocharging Service Station.
Rotor rubbing Check clearances (see chapter Radial clearances
N and R 78). If clearances are outside the tol-
erance or if in doubt, contact an ABB Turbochar-
ging Service Station.
Foreign object in the tur-
bocharger
Dismantle turbocharger (see chapter Dismant-
ling and fitting 56). In case of damage, re-
place the corresponding parts or contact an ABB
Turbocharging Service Station.
Table24: Malfunctions when stopping – Runout noises
Runout time too short
The runout time must be noted down as a reference. Because the runout time depends on
the oil viscosity, the runout time must always be measured at the same oil temperature.
If the runout time is significantly shorter in comparison to a previous measurement, the fol-
lowing table must be observed.
Possible causes Remedy
Turbochar-
ger
Turbocharger contaminated Clean (see chapter Periodic maintenance work
39)
Bearing damaged Check clearances (see chapter Axial clearance A
and radial clearance B 71). If clearances are
outside the tolerance or if in doubt, contact an
ABB Turbocharging Service Station.
Rotor rubbing Check clearances (see chapter Radial clearances
N and R 78). If clearances are outside the tol-
erance or if in doubt, contact an ABB Turbochar-
ging Service Station.
Foreign object in the tur-
bocharger
Dismantle turbocharger (see chapter Dismant-
ling and fitting 56). In case of damage, re-
place the corresponding parts or contact an ABB
Turbocharging Service Station.
Table25: Malfunctions when stopping – Runout time too short