Rockwell Automation Publication KNX-RM003B-EN-P - March 2019 85
Kinetix 6000 and Kinetix 6200/6500 Drive Systems
Kinetix 6000 and Kinetix 6200/6500 (400V-class) Drives/MP-Series Linear Stage Curves (continued)
Force
(N)
Force
(lb)
45.0
89.9
134.9
179.8
224.8
269.8
0
200
400
600
800
1000
1200
1400
314.7
0
Velocity (mm/s)
50
200150
0
300
250
100
2094-BMP5-S @ 150% or 2094-BMP5-M
and MPAS-B8xxx1-V05SxA
1020 mm
900 mm
< 780 mm
Intermittent curve
represents 460V and
400V inputs
Force
(N)
Force
(lb)
1000
800
600
400
200
0
224.8
179.8
134.9
89.9
45.0
0
Velocity (mm/s)
200
800600
0
1200
1000
400
2094-BMP5-S @ 250% or 2094-BMP5-M
and MPAS-B8xxx2-V20SxA
< 660 mm
1020 mm
900 mm
780 mm
Intermittent curve
represents 460V and
400V inputs
Velocity (mm/s)
0
3000
5000
40001000
2000
Force
(N)
Force
(lb)
2094-BMP5-S @ 250% or 2094-BMP5-M
and MPAS-B8xxxF-ALMO2C
800
700
600
500
400
300
200
100
0
179.8
157.4
134.9
112.4
89.9
67.4
45.0
22.5
0
Velocity (mm/s)
0
3000
5000
40001000
2000
Force
(N)
Force
(lb)
2094-BMP5-S @ 250% or 2094-BMP5-M
and MPAS-B8
xxxF-ALMS2C
800
700
600
500
400
300
200
100
0
179.8
157.4
134.9
112.4
89.9
67.4
45.0
22.5
0
Force
(N)
Force
(lb)
45.0
89.9
134.9
179.8
224.8
269.8
0
200
400
600
800
1000
1200
1400
314.7
0
Velocity (mm/s)
50
200150
0
300
250
100
2094-BMP5-S @ 150% or 2094-BMP5-M
and MPAS-B9xxx1-V05SxA
1020 mm
900 mm
< 780 mm
Intermittent curve
represents 460V and
400V inputs
Force
(N)
Force
(lb)
1000
800
600
400
200
0
224.8
179.8
134.9
89.9
45.0
0
Velocity (mm/s)
200
800600
0
1200
1000
400
< 660 mm
1020 mm
900 mm
780 mm
2094-BMP5-S @ 250% or 2094-BMP5-M
and MPAS-B9xxx2-V20SxA
Intermittent curve
represents 460V and
400V inputs
= Intermittent operating region
= Continuous operating region
= System operation with 400V AC rms input voltage
= System operation for specified stroke length

Table of Contents

Other manuals for Allen-Bradley Kinetix 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Kinetix 6000 and is the answer not in the manual?

Allen-Bradley Kinetix 6000 Specifications

General IconGeneral
BrandAllen-Bradley
ModelKinetix 6000
CategoryServo Drives
LanguageEnglish

Related product manuals