Table 5-27: Protocol Management, ini File Parameters (continues on pages 111 to 113)
ini File Parameter
Name
Valid Range and Description
MeteringType
Defines the metering tone (12 kHz or 16 kHz) that is detected by FXO gateways and
generated by FXS gateways.
0 = 12 kHz metering tone (default).
1 = 16 kHz metering tone.
Note: Suitable (12 kHz or 16 KHz) coeff file must be used for both FXS and FXO
gateways.
PolarityReversalType
Defines the voltage change slope during polarity reversal or wink.
0 = Soft (default).
1 = Hard.
Note 1: Some Caller ID signals use reversal polarity and/or wink signals. In these cases
it is recommended to set PolarityReversalType to 1 (Hard).
Note 2: Applicable only to FXS gateways.
CurrentDisconnectDuratio
n
Duration of the current disconnect pulse (in msec).
The default is 900 msec, The range is 200 to 1500 msec.
Applicable for both FXS and FXO gateways.
Note: The FXO gateways’ detection range is +/-200 msec of the parameter’s value +
100.
For example if CurrentDisconnectDuration = 200, the detection range is 100 to 500
msec.
CurrentDisconnectDefault
Threshold
Determines the line voltage threshold which, when reached, is considered a current
disconnect detection.
Note: Applicable only to FXO gateways.
The valid range is 0 to 20 Volts. The default value is 4 Volts.
TimeToSampleAnalogLine
Voltage
Determines the frequency at which the analog line voltage is sampled (after offhook), for
detection of the current disconnect threshold.
Note: Applicable only to FXO gateways.
The valid range is 100 to 2500 msec. The default value is 1000 msec.
AnalogCallerIDTimimgMod
e
0 = Caller ID is generated between the first two rings (default).
1 = The gateway attempts to find an optimized timing to generate the Caller ID according
to the selected Caller ID type. Note that when used with distinctive ringing, the Caller ID
signal doesn’t change the distinctive ringing timing.
Note: Applicable only to FXS gateways.
EnableRAI
0 = Disable RAI (Resource Available Indication) service (default).
1 = Enable RAI service.
If RAI is enabled, an SNMP ‘acBoardCallResourcesAlarm’ Alarm Trap is sent if gateway
resources fall below a predefined (configurable) threshold.
RAIHighThreshold
High Threshold (in percentage) that defines the gateway‘s busy endpoints.
The range is 0 to 100.
The default value is 90%.
When the percentage of the gateway‘s busy endpoints exceeds the value configured in
High Threshold, the gateway sends an SNMP ‘acBoardCallResourcesAlarm’ Alarm Trap
with a ‘major’ Alarm Status.
Note: The gateway’s available Resources are calculated by dividing the number of busy
endpoints by the total number of available gateway endpoints.
RAILowThreshold
Low Threshold (in percentage) that defines the gateway‘s busy endpoints.
The range is 0 to 100.
The default value is 90%.
When the percentage of the gateway’s busy endpoints falls below the value defined in
Low Threshold, the gateway sends an SNMP ‘acBoardCallResourcesAlarm’ Alarm Trap
with a ‘cleared’ Alarm Status.
RAILoopTime
Time interval (in seconds) that the gateway checks for resource availability.
The default is 10 seconds.

Table of Contents

Other manuals for AudioCodes MediaPack MP-108

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-108 and is the answer not in the manual?

AudioCodes MediaPack MP-108 Specifications

General IconGeneral
BrandAudioCodes
ModelMediaPack MP-108
CategoryGateway
LanguageEnglish

Related product manuals