MediaPack SIP User’s Manual 5. Configuring the MediaPack
Version 4.6 113 June 2005
Table 5-27: Protocol Management, ini File Parameters (continues on pages 111 to 113)
ini File Parameter
Name
Valid Range and Description
Serial parameters (applicable only to the VM SMDI application)
SerialBaudRate
Determines the value of the RS-232 baud rate.
The valid range is: any value.
It is recommended to use the following standard values:
1200, 2400, 9600 (default), 14400, 19200, 38400, 57600, 115200.
SerialData
Determines the value of the RS-232 data bit.
7 = 7-bit.
8 = 8-bit (default).
SerialParity
Determines the value of the RS-232 polarity.
0 = None (default).
1 = Odd.
2 = Even.
SerialStop
Determines the value of the RS-232 stop bit.
1 = 1-bit (default).
2 = 2-bit.
SerialFlowControl
Determines the value of the RS-232 flow control.
0 = None (default).
1 = Hardware.