Configure the SNTP Protocol Using Web Based Management
Related Models: ADS-1350W/ADS-1800W
Configure the SNTP protocol to synchronise the time the machine uses for authentication with the time kept by
the SNTP time server.
This feature is not available in some countries.
1. Start your web browser.
2. Type "https://machine's IP address" in your browser's address bar (where "machine's IP address" is the
machine's IP address).
For example:
https://192.168.1.2
3. If required, type the password in the Login field, and then click Login.
The default password to manage this machine’s settings is located on the bottom of the machine and
marked "Pwd". Change the default password by following the on-screen instructions when you first log in.
4. In the left navigation bar, click Network > Network > Protocol.
If the left navigation bar is not visible, start navigating from
.
5. Select the SNTP checkbox to activate the settings.
6. Click Submit.
7. Restart your Brother machine to activate the configuration.
8. Next to the SNTP checkbox, click Advanced Settings and configure your settings as needed.
Option Description
Status Displays whether the SNTP protocol is enabled or disabled.
Synchronization Status Confirm the latest synchronisation status.
SNTP Server Method Select AUTO or STATIC.
• AUTO
If you have a DHCP server in your network, the SNTP server will obtain
the address from that server automatically.
• STATIC
Type the address you want to use.
Primary SNTP Server
Address
Secondary SNTP Server
Address
Type the server address (up to 64 characters).
The secondary SNTP server address is used as a backup to the primary
SNTP server address. If the primary server is unavailable, the machine will
contact the secondary SNTP server.
Primary SNTP Server Port
Secondary SNTP Server
Port
Type the port number (1-65535).
The secondary SNTP server port is used as a backup to the primary SNTP
server port. If the primary port is unavailable, the machine will contact the
secondary SNTP port.
Synchronization Interval Type the number of hours between server synchronisation attempts (1-168
hours).
9. Click Submit.