0-16
ELECTRICAL PARTS INSPECTION
1. Always disconnect the battery plug before inspecting or servicing electrical parts.
2. Pay sufficient attention when handling electronic parts.
(1) Never subject electronic parts, such as computers
and relays, to impact
(2) Never expose electronic parts to high temperature or
moisture
(3) Do not touch connector terminals, as they may be
deformed or damaged due to static electricity
3. Use a circuit multimeter that matches the object and purpose of measurement.
Analog type: This type is convenient for observing movement during operation and the operating
condition. Measured value is only a reference
Digital type: A fairly accurate reading is possible. However, it is difficult to observe operation or
movement.
(1) Difference between results of measurement with analog and digital types
∗ The results of measurements using the analog type and the digital type may be different.
Differences between the polarities of the analog type and the digital type are described below.
1) Analog circuit multimeter
Example of measurement result
Multimeter range: 1 kΩ
2) Digital circuit multimeter
Example of measurement result
Multimeter range: 2MΩ
Forward
Reverse
Analog type
Forward
Continuity
11 kΩ
Reverse
No continuity
∞
Forward
Reverse
Digital type
Forward
No continuity
1
Reverse
Continuity
2 MΩ
https://www.forkliftpdfmanuals.com/

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CESAB B 215 and is the answer not in the manual?

CESAB B 215 Specifications

General IconGeneral
BrandCESAB
ModelB 215
CategoryForklifts
LanguageEnglish

Related product manuals