EasyManuals Logo
Home>CESAB>Forklifts>B 215

CESAB B 215 User Manual

Default Icon
460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
2-24
INSPECTION
1. MB (power supply contactor)
Inspection method.
Disconnect the connector from the wiring harness and
measure the resistance of the coil.
2. FUSE
Inspection method.
Disconnect the fuse and measure the insulation
resistance
Part to be
inspected
Measurement
measurament
Standard
Tester
range:
Coil CT1
Both
coil terminals
Approx.
104 Ω
Ω × 1
Coil CT2
Both
coil terminals
Approx. 45
Ω
Ω × 1
Part to be
inspected
Measurement
measurament
Standard
Tester
range:
FUSES
Both
fuse
terminals
0 ΩΩ × 1