Port ErrDisabled
Possible Cause Solution
The cable is defective or
damaged.
1. Verify the physical cabling.
2. Replace or repair defective cables.
3. Reenable the port.
shut
no shut
You attempted to add a port
to a port channel that was
not configured identically,
and the port is then
errdisabled.
1. Display the switch log file and identify the exact configuration error
in the list of port state changes.
show logging logfile
2. Correct the error in the configuration and add the port to the port
channel.
3. Re-enable the port.
shut
no shut
A VSM application error
has occurred.
1. Identify the component that had an error while you were bringing up
the port.
show logging logfile | grep interface_number
See Example 9-7 on page 9-13.
2. Identify the error transition.
show system internal ethpm event-history interface
interface_number
3. Open a support case and submit the output of the above commands.
For more information see the “Contacting Cisco or VMware
Customer Support” section on page 1-7.

Table of Contents

Other manuals for Cisco Nexus 1000V

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Nexus 1000V and is the answer not in the manual?

Cisco Nexus 1000V Specifications

General IconGeneral
TypeVirtual Switch
ManageableYes
NetFlowYes
SPANYes
ERSPANYes
Operating SystemCisco NX-OS
Form FactorVirtual
Hypervisor SupportVMware ESXi
FeaturesVXLAN
Security FeaturesPort Security, Private VLANs, ACLs

Related product manuals