8-40
8.2.12 F.PTI specification (Applicable models:LXE10E-A12(AtoE) and A28)
In order to perform F.PTI operation, this unit is designed by adding the following to functions to the
standard specification, which are enclosed with a dotted rectangular as shown below.
Entry of set temperature while in F.PTI mode
Display of set temperature and pull-down period while in F.PTI mode
Use the or key to change the set
temperature.
M
S
I/O
DEHUMID
I/O
DEHUMID
Setting range: -18°C to -30°C (in 1°C increments)
      (The temperature is displayed on LCD.)
Furthermore, the defrost interval returns to 12 hours.
When the F.PTI operation terminates, the set temperature will
automatically return to the default value, that is, -18°C.
FULL PTI
SHORT PTI
MANUAL PTI
Press the   key. You should see the temperature
setting screen.
After the completion of the temperature setting, press
the key to commence the F.PTI operation.
Temp. setting
(variable)
Display on LCD
Set temperature Pull-down period
In the case of 2 hours and 5 minutes
Scrolling sensor display mode with the UP or DOWN key will display the temperature
and period after DRS.
HPT ○○
T 02H05
SP −○○
〜
08LXE10E-A(40-44)07.2.204:37PMページ8-40
https://daikin-p.ru

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin LXE10E-A and is the answer not in the manual?

Daikin LXE10E-A Specifications

General IconGeneral
BrandDaikin
ModelLXE10E-A
CategoryAir Conditioner
LanguageEnglish

Related product manuals