8-50
CAUTION
1. Use the pressure indicating function
of the controller to check the working
pressure as much as possible
instead of using the gauge manifold
in order to prevent foreign particles
or moisture from mixing into the
refrigerant system.
2.
Do not use any of the pressure gauge,
gauge manifold, charge hose and
charging cylinder which have been
used for CFC12 in order to prevent
refrigerant or refrigerant oil of a
different kind from mixing.
8.6.1 Collection of refrigerant
qWhen release the refrigerant from the
refrigerant system, be sure to use a
refrigerant recovery unit to protect the ozone
layer around the earth from depletion.
w
Observe strictly all the environmental laws
relating with to the country where the repair
service is conducted.
8.6.2 Attaching and removing of
manifold gauge
(1) Attaching the gauge manifold
Remove the service port cap using 2 spanner
and attach the charging hose to service port,
then turn the part A by band to tighten.
Cup
A
8.6 Special service port (Applicable models:LXE10E-A23(A,B))
08LXE10E-A(50-54)07.2.2310:51AMページ8-50
https://daikin-p.ru

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin LXE10E-A and is the answer not in the manual?

Daikin LXE10E-A Specifications

General IconGeneral
BrandDaikin
ModelLXE10E-A
CategoryAir Conditioner
LanguageEnglish

Related product manuals