INSTALLATION
EPT019297 Issue 1 November 2016 3-3
PRINTER INSTALLATION
Cabinet Positioning
WARNING: Care must be taken when moving the printer to avoid injury. Only
personnel who have completed manual handling training and have
the appropriate equipment should carry out this task.
Note: For printer dry weight, see the specification on page 2-8.
The cabinet must be positioned in a location with enough clearance to open the doors and give
access to the cabinet’s front and rear. The cabinet must also be positioned on a level surface and
electrically isolated from other equipment, except for a normal data interface.
The printer must be positioned in an area where the temperatures will remain within +5°C and
+45°C (42ºF to 112ºF) and the relative humidity must remain within 10% to 90%
(non-condensing).
The printer draws in and expels cooling air through vents underneath of the cabinet. The air vents
must not be obstructed.