INSTALLATION
EPT019297 Issue 1 November 2016 3-33
(18) If missing strokes appear in the test print change the Stroke go multiplier setting to x2. This
will increase the Encoder stroke resolution (pulses/stroke) by detecting a pulse on both the
rising and falling edge of the shaft encoder input signal.
(19) If missing strokes continue to appear in the test print, the Encoder stroke resolution
(pulses/stroke) can be accurately set using the Digital gearbox multiplier and Digital gearbox
divider settings. It is recommended to set Encoder stroke resolution (pulses/stroke) value
between 20 to 40 using the lowest possible Digital gearbox multiplier value. The Encoder
stroke resolution (pulses/stroke) value can be set higher if required for printing 2D barcodes.
Note: The Save button will not be available for selection if the Encoder stroke resolution
(pulses/stroke) is set too high. The Encoder stroke resolution (pulses/stroke) range is
1 - 100.
(20) If there is noise on the shaft encoder input causing a false signal, change the Encoder
persistence (ms) value. This value sets the length of time the shaft encoder signal must be
active for before the printer recognises the signal as valid (Default value: 0.001).
Note: Set the persistence value as low as possible. If a high value is set then the accuracy of
the shaft encoder will be affected.
End of procedure.