135
© 2017 Eaton. All rights reserved
2018.12.12
Shift Bar Housing Disassembly and Assembly | Service Procedures TRSM0940
Shift Bar Housing Disassembly
1. Remove the three Detent Spring Caps from the Shift
Bar Housing.
2. Tilt th
e Shift Bar Housing on its side to remove the
springs and balls from the housing bores.
3. Place the
Shift Bar Housing assembly upside down on
a flat workspace. (The front of the housing facing to the
left.)
4. Cut and remove the lock wire from
the Shift Bar retain-
ing cap screws.
Note: S
tart with the upper Shift Bar, move all bars to
the right and out the rear boss bore.
5. Remove Shift
Bar retaining cap screws
6. Move
the 4th-5th Gear Shift Bar to the housing rear,
removing the yoke and block from the bar.
7. Move
the 2nd-3rd Gear Shift Bar to the housing rear,
removing the yoke and block from the bar.
8. Remove the small
interlock pin from the bore as the
Neutral notch in the bar clears the rear boss bore.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton UltraShift PLUS FOM-16E310C-LAS and is the answer not in the manual?

Eaton UltraShift PLUS FOM-16E310C-LAS Specifications

General IconGeneral
BrandEaton
ModelUltraShift PLUS FOM-16E310C-LAS
CategoryMicrophone system
LanguageEnglish

Related product manuals