TRSM0940 Service Procedures | Shift Bar Housing Disassembly and Assembly
9. Move the short 1st-Reverse Gear Shift Bar to the hous-
ing rear, removing the yoke from the bar.
10. Remove th
e actuating plunger from the center boss
bore.
11. Tilt
the Shift Bar Housing on its side to remove the two
3/4" interlock balls from the housing bore.