139
© 2017 Eaton. All rights reserved
2018.12.12
Shift Bar Housing Disassembly and Assembly | Service Procedures TRSM0940
13. Install the block and yoke lock screws, tighten and lock
wire securely.
14. After all lock s
crews and safety wire have been
installed, flip the Shift Bar Housing over.
15. Install
the three tension balls and springs into the
bores on the top of the Shift Bar Housing.
16. Install the Detent
Spring Caps over the springs in each
bore; thread in and torque 12–15 lb-ft.