72
TRSM0940 Service Procedures | VCS/VMS Combination Cylinder Disassembly and Assembly
Procedure – Combination Cylinder Assembly -
VCS, VMS
1. Install the small O-Ring in the Range and Reduction
cylinder housing bores. Lightly lubricate O-rings with
Eaton® silicone lubricant #71206 or equivalent.
2. Install
the Range and Reduction Piston O-rings on the
pistons’ I.D. and O.D. Lightly lubricate O-rings with
Eaton® silicone lubricant #71206 or equivalent.