Maintenance 11. Lithium Battery and Boards
140 LS20 Rev.4
11.1 Replacing the Battery Unit (Lithium Battery)
battery)
controller.
Plate.
Maintenance: 3.4 Connector Plate.
Remove the resolver plate from the connector plate.
Be careful not to disconnect the battery connector.
Do not remove the signal cable and the M/C cable.
you disconnect all the current batteries before connecting the new battery, the robot
the home position data and the calibration must be executed again. The
battery units are exchanged according to the following procedures.
off the wire tie binding the lithium batteries to the battery plate.
Bind new batteries to the battery plate with a new wire tie.
6)
Disconnect one connector of the old three batteries and connect a new one.
7)
batteries connector and connect new ones.
8)
resolver plate to the connector plate.
9)
0)
Check if the manipulator moves to points correctly in correct orientation.
To do so, select some points already registered
and move the manipulator to the points.
1)
manipulator does not move to the points correctly, execute
the calibration of all
joints and axes.
Maintenance: 13. Calibration.