4.1 Call up for Option Menu
4-1
4.1 Call up for Option Menu
MMSI, Channel and Power settings can be set up by going to SYSTEM menu and then
to “option”. Following is the procedure.
Procedure
1. With the power off, make a jumper connection between 2 and 15 of
[PRINTER] port. Or, jumper connection between #25 and #26 of IF-8810.
However, it is correspondence from production in December 2005.
Chapter 4. System Setting
PRINTER
Jumper between #2 and #15
Adjustment of LCD Dimmer: [SHIFT] -> [2]
Adjustment of LCD Contrast: [SHIFT] -> [SHIFT], [LOG] or CHANNEL knob
J1: [PRINTER]
TB1
J2: [IEC61162-1/REMOTE]
1
2
3
4
13
14
15
16
STROBE N
D0
D1
D2
SELECT
ALF N
ERROR N
INIT N
1
2
3
4
5
6
7
8
+15VDC
+15VDC
+15VDC
+15VDC
N.C
N.C
TXD(H)
RXD(C)
Jumper
#2 - #15
Jumper
#25 - #26
24
25
26
27
NOT USED-1
NOT USED-2
FM-8800S/D
IF-8810
CPU
(05P0773)
IF-8810