Revision History
5495975-1EN Rev.9 i-v
© 2013-2017 General Electric Company. All rights reserved.
8 23 Jan 2017 To add Standard Table & Manual Wallstand and upgraded Collimator, detailed
revise happened together with having corrected legend errors as below.
1. In chapter 2: Revised Table 2-5 Maximum Attenuation Equivalent mm AL with
adding new items and correcting legend errors under section General Use Warn-
ings; Revised Table 2-14 Identification Plate with adding new items and correcting
legend errors under section Identification Plate and Compliance Plates Location;
Added
a new section Standard Table Warning Labels under section NRTL Listed
Label; Added a warning for standard table load capability under section Patient
Positioning Warnings;
2. In chapter 4: Revised Figure 4-8 Emergency Stop buttons and corrected a Cau-
tion under section Emergency Stop.
3. In chapter 5: Corrected a Caution under section Emergency Stop button.
4. In chapter 7: Added “Do not stand on the grid” under section Grid Handling.
5. In chapter 8: Revised the configurations and the note in section Configurations;
Revised Table 8-1 Major system components with adding new components under
section Component Identification; Revised Table 8-2 Available Options with adding
new options under section Available Accessories; Revised multi-leaf collimator
description and Figure 8-13 Collimator controls under section Multi-Leaf Collimator;
Revised Figure 8-14 Multi-leaf collimator display under section Collimator Display; In
section Digital Wallstand, added word “digital” in several places in order to differen-
tiate Digital Wallstand with new Manual Wallstand; added Wallstand chin rest as
applied part. Added a new section Manual Wallstand after section Digital Wall-
stand; In section Digital Table, added word “digital” in several places in order to dif-
ferentiate Digital Table with new Standard Table; revised a Caution of item 7 in table
8-13, too. Added a new section Standard Table after Digital Table section; Revised
section Digital Cassette Imaging in Extended Table Detector Tray with clinical input;
Added a new section Standard Table Hand Grips and Compression Band after sec-
tion Digital Table Hand Grips and Compression Band; Corrected an error on Lateral
Bridge Lengths by deleting 4.5 meter bridge (option).
6. In chapter 10: Added a Caution for labeling mitigation following up; Added a note
in section Conduct a Wallstand Exam. Added a note in section Conduct a Table Top
Exam and section Conduct a Cassette Exam.
7. In chapter 13: deleted “(not available in USA)” at the title “Dual Energy”.
8. In chapter 14: corrected the wrong service documentation part numbers under
section General and Periodic Maintenance Schedule.
9. In chapter 15: corrected an error in the first paragraph under section Add or Edit
DICOM Printers; Added a caution into section Retrieve Protocol Database from CD or
DVD.
10. In Appendix B: added specifications for new Standard Table and Manual Wall-
stand. Meanwhile corrected some legend errors on OTS, tables, Wallstand and stor-
age conditions.
What is more, Labeling category was cleaned up throughout this manual. Copyright
time was revised through this manual, too.
Revision History
Revision Date Description of Change