GPT-9000/9000A Series User Manual
146
MANU:GB:ZEROCHECK
Set
Query
Description
Performs the zero check function. The test must
first be in GB mode and in the Ready Status before
this command can be used.
See page 73 for details on the ZERO function.
Syntax
Query Syntax
MANU:GB:ZEROCHECK {ON|OFF}
MANU:GB:ZEROCHECK?
Parameter/
Return parameter
ON
Zero function is active.
OFF
Zero function is not active.
Example
MANU:GB:ZEROCHECK OFF
Activates the ZERO function.
MANU:UTILity:ARCMode
Set
Query
Description
Sets or returns the ARC mode status for the
current test.
The ARC mode cannot be set for the IR and GB
function.
Syntax
Query Syntax
MANU:UTILity:ARCMode {OFF|ON_CONT|
ON_STOP}
MANU:UTILity:ARCMode?
Parameter/
Return parameter
OFF
Turns ARC mode off.
ON_CONT
Sets ARC mode to ON and
CONTINUE.
ON_STOP
Sets ARC mode to ON and STOP.
Example
MANU:UTIL:ARCM OFF
Turns ARC mode OFF.
w ww . . co m
information@itm.com1.800.561.8187
All manuals and user guides at all-guides.com
all-guides.com

Table of Contents

Other manuals for GW Instek GPT-9000 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek GPT-9000 series and is the answer not in the manual?

GW Instek GPT-9000 series Specifications

General IconGeneral
BrandGW Instek
ModelGPT-9000 series
CategoryTest Equipment
LanguageEnglish

Related product manuals