EasyManuals Logo
Home>Hardi>Farm Equipment>SMARTCOM ISOBUS UT SW A.2.2 Series

Hardi SMARTCOM ISOBUS UT SW A.2.2 Series User Manual

Hardi SMARTCOM ISOBUS UT SW A.2.2 Series
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
5 - Operation
100
Cleaning
Start AutoWash
Procedures for using AutoWash programs.
μ
ATTENTION! Refer to “AutoWash on page 24 for description of AutoWash functions.
Preconditions
In order to start a AutoWash program the following must be fulfilled:
The pump need to be set into the correct RPM range:
μ
ATTENTION! When AutoWash has ended and main ON/OFF is being activated, then both the suction and pressure
valves automatically turn back to positions used when spraying.
Precondition Cause
MainTank content below 40 litres. The MainTank need to be empty to be able to clean it with FastFlush or MultiRinse programs. This is not necessary to
run a BoomFlush.
RinseTank completely full. In case the amount of water in the RinseTank is not enough for the selected AutoWash program, the Controller will
prompt “Not enough rinse water”. You will need to fill the RinseTank before attempt to use the AutoWash program
again.
TurboFiller is cleaned prior to AutoWash. If the TurboFiller is rinsed after running AutoWash, chemicals might have entered the FastFiller line. The FastFiller line
is not cleaned, when performing a TurboFiller rinsing!
CycloneFilter 3 position valve is open. If the 3 position valve is closed AutoWash cannot flush boost line.
Pressure draining coupler must be closed
with a plug.
If open or not tightly closed, water with chemical will exit when flushing this line.
FastFiller valve is closed (when not
equipped with AutoFill).
If open, a pocket of water with chemical will not get flushed out.
Nozzle carousel is not set on a blind nozzle. Blind nozzles at boom tube ends will cause pocket of water with chemical not flushed out.
Valve for external cleaning (hosing) is
closed.
Rinse water may float out if not closed.
The sprayer fluid system must be well
maintained and able to operate as
designed.
Filters must not be clogged or cause large pressure drop, no leaks from the fluid system or faulty sensors.
PTO revolutions set to RPM’s according to
table below.
In case PTO revolutions is outside range the display will show one of the warnings:
“Pump RPM is too low, increase”.
“Pump RPM is too high, decrease”.
Pump Model PTO Low limit RPM PTO High limit RPM
464 540RPM
464 10.0
486 540
463H 540RPM
463H 540RPM FlexCapacity
464 12.0
417 463
463 1000RPM
464 5.5
814 905
463H 1000RPM
463H 1000RPM FlexCapacity
464 6.5
714 793

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hardi SMARTCOM ISOBUS UT SW A.2.2 Series and is the answer not in the manual?

Hardi SMARTCOM ISOBUS UT SW A.2.2 Series Specifications

General IconGeneral
BrandHardi
ModelSMARTCOM ISOBUS UT SW A.2.2 Series
CategoryFarm Equipment
LanguageEnglish

Related product manuals