EasyManuals Logo
Home>Hardi>Farm Equipment>SMARTCOM ISOBUS UT SW A.2.2 Series

Hardi SMARTCOM ISOBUS UT SW A.2.2 Series User Manual

Hardi SMARTCOM ISOBUS UT SW A.2.2 Series
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #119 background imageLoading...
Page #119 background image
7 - Fault Finding
119
Overview of Fuses
The fuses have a short text print nearby the socket, that refer to the function it protects. The schematic below shows an
overview of fuses and functions. Be aware that the fuse size and location can very, depending on the specific sprayer setup.
μ
ATTENTION! The recommended fuses to be used, are Littelfuse ATOF® blade fuses rated 32 V, unless otherwise
mentioned.
To verify the correct printed circuit board when inspecting a fuse, check the HARDI item number printed on the board.
Printed Circuit Board PDU Board Item
Number
Assigned Sprayer
Function
Fuse Socket Fuse Rating Fuse Item
Number
PCB
Function
Connector
Power Distribution Unit PDU 2 26070200 F1 AUX 1 X1007
- F2 5 A* 261762 AUX 2 X1004
F3 Guest (F3) X400
- F4 25 A 261605 ECU-IO X700
- F5 25 A 261605 ECU Master X600
Power Distribution Unit PDU 3 26070300 - F1 15 A** 28048600 AUX 1 X1004
F2 AUX 2 X1007
- F3 10 A** 28048500 Guest 1 X400
F4 AUX SW 1 X1001
F5 AUX SW 2 X1003
F6 Guest 2 X500
- F7 25 A 261605 ECU-IO 1 X700
- F8 25 A 261605 ECU Master X600
- F9 25 A 261605 ECU-IO 2 X800
* with FillStop
** with AutoSlant/AutoHeight/AutoTerrain UC7
Power Distribution Unit PDU 2
Location: Front
Sprayer:
NAVIGATOR i with IntelliTrack
MEGA M
26070200 F1 AUX 1 X1007
F2 AUX 2 X1004
F3 Guest (F3) X400
- F4 25 A 261605 ECU-IO X700
- F5 25 A 261605 ECU Master X600
Power Distribution Unit PDU 2
Location: Front
Sprayer:
NAVIGATOR with manual valves
26070200 F1 AUX 1 X1007
F2 AUX 2 X1004
- F3 5 A 261762 Guest (F3) X400
- F4 25 A 261605 ECU-IO X700
- F5 25 A 261605 ECU Master X600
Power Distribution Unit PDU 3
Location: Front
Sprayer:
NAVIGATOR i
26070300 - F1 15 A 28048600 AUX 1 X1004
F2 AUX 2 X1007
- F3 5 A 261762 Guest 1 X400
F4 AUX SW 1 X1001
F5 AUX SW 2 X1003
F6 Guest 2 X500
- F7 25 A 261605 ECU-IO 1 X700
- F8 25 A 261605 ECU Master X600
- F9 25 A 261605 ECU-IO 2 X800
Power Distribution Unit PDU 2
Location: Centre Section
Sprayer:
NAVIGATOR Y-version
26070200 F1 AUX 1 X1007
F2 AUX 2 X1004
F3 Guest (F3) X400
- F4 25 A 261605 ECU-IO X700
- F5 25 A 261605 ECU Master X600

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hardi SMARTCOM ISOBUS UT SW A.2.2 Series and is the answer not in the manual?

Hardi SMARTCOM ISOBUS UT SW A.2.2 Series Specifications

General IconGeneral
BrandHardi
ModelSMARTCOM ISOBUS UT SW A.2.2 Series
CategoryFarm Equipment
LanguageEnglish

Related product manuals