3 - Description
27
AutoFill
Use AutoFill when filling the sprayer totally or filled to a specified amount of water.
Key in the specified amount to the display. Press for “Edit filled” and key in the volume to AutoFill. The filling is started
by pressing on the FluidBox.
FluidBox Buttons
When a filling amount has been keyed in at the display, then 4 buttons become active on the FluidBox:
• button: Used to stop any filling.
• button: Opens the FastFiller valve and activates monitoring for stop.
• button: Opens the FastFiller valve. Monitoring for stop not activated.
• button: Closes the FastFiller valve to abort the filling process.
μ
ATTENTION! If the system has to be stopped when filling: Press the or the button on the FluidBox or on
the display.
μ
ATTENTION! If the filling process is paused and then resumed by pressing then AutoFill will fill the tank all way till
top! Therefore use to resume if the keyed in amount of water is to be kept.
AutoAgitation
AutoAgitation is fully automatic and consists of an electrically operated flow valve and the TankGauge sensor. Thereby
SmartCom VT controls the flow for the agitation. This is a standard feature with AutoFill and/or AutoWash.
With a full tank, AutoAgitation will ensure maximum agitation. As the tank empties, the computer regulates the flow to
prevent foam, and minimises liquid residues when the tank is empty.
Different programmes can be selected for optimal agitation. Refer to “Menu 2.2 Auto functions” on page 47.
A manual override is possible from the FluidBox, by pressing the buttons for zero, half or full agitation.